  • RS-232 to RS-422/RS-485 Converter

    ND-6520 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • Universal Cable/Harness Tester

    LX-686 - Shenzhen Lian Xin Technology Co., Ltd.

    The system provides Chinese/English free switch operation interface,.·Up to 1500Vdc/1000Vac Test Voltage ,.·256 Max. Test Points , (Max of all series).·500 Max Files Memory,support USB or PC unlimited expansion,.·Arc detection level 0-9 ,auto prompt.·Adopted high resolution colour 640*480 TFT LCD ,.·Providing Single-End ,Multi-segment ,Standard ,and Spot test of wire..·Auto Scan and Auto Pin Search ,.·The system provides advanced instant open-circuit, short-circuit, continuity test,.·Intermittent Conductance Test,.·Intermittent Open/Short Test ,.·Full Programming Sequence Test ,.·Versatile I/O Ports for application ,.·Statistics and Print Function,.·Provide REMOTE interface, communicate with PLD auto test fixture,.·Provide personalized customization according to different requirements,

  • New GEL Battery CCA Tester

    Hangzhou Xun Anda Electrical Co., Ltd.

    1. Test application: 12V/6V batteries test and 12V /24V Starting /Charging system test.2. Test battery type: regular liquid, AGM battery, GEL battery.VRLA battery 3. CCA test range: 40~2000CCA (SAE).4. Voltage test range: 1.5-30V.5. Display SOH (state of health), SOC(state of charge).6. Test for multiple battery standards: SAE, DIN, EN, IEC, CA.JIS7. Graphic LCD display with back light, LCD brightness adjustable.8. Multigle language operation: English, Chinese, Germany, French, Spanish.9. Intergrated thermal printer to print test reports.10. Thermal printer paper roll is 58mm width and 7.5m long. 11.test internal resistance

  • USB to RS-422/RS-485 Converter

    ND-6530 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • Amp, Power Factor & VAR Recorder

    Varcorder - SensorLink

    The Varcorder measures and records Amps and Power Factor. A voltage constant is then applied in software to calculate VARs. The Varcorder uses the same current sensor technology as the original Ampstik. This patented amp sensor does not use magnetic materials and has no moving parts. The opening of the sensor is electronically closed, and external currents are electronically rejected. The accuracy, external current reject, and range of currents measured by the patented amp sensor substantially exceed the performance of the best clamp-on sensors. The true power factor is calculated by measuring the electric field in comparison with the current reported from the amp sensor. The key feature of the unit is the ability to leave it deployed on the line to record readings every 15 minutes for 90+ days. It easily attaches to the line with a standard shotgun style hotstick. Once on the line, it immediately begins to collect and record the current and power factor on the line.

  • Measurement System for ESD Protection

    SampleProtect - Oxford Instruments plc

    The SampleProtect measurement system is ready to go, and comes complete with Oxford Instruments’ Cryofree bottom loading cryostat – the OptistatDry BLV, Zurich Instruments’ MFLI Lock-in Amplifier, a specially designed ESD break-out box and high quality measurement grade cables. The patent-pending puck style mounting from Oxford Instruments provides safe installation of your samples. The MFLI 500 kHz Lock-in Amplifier (capable of 500 kHz demodulation as standard) with MF-MD multi-demodulator capability brings the benefits of high performance signal processing at low and medium frequencies. The differential voltage and current inputs of the MFLI are optimised for low noise operation and the high oversampling rate ensures an even better signal to noise ratio. Zurich Instruments’ unique LabOne® control software provides a toolset including an integrated oscilloscope, a spectrum analyser, a plotter and a parameter sweeper.

  • Engineering Support Platform

    ESP - ARC Technology Solutions

    ESP, or Engineering Support Platform, is a low cost, powerful and versatile platform for the development, deployment and support of FPGA Applications. ESP is powered by DSX core, ARC’s core element for the development and deployment of digital and mixed signal systems. The standard system contains 2 custom FPGA system, often configured in combination where one acts as the application firmware, and the other is used for test. But the system is expandable and configurable in any combination to solve any problem in a digital, analog or mixed signal system. The FPGAs can be configured to generate, analyze, process and/or output complex signals at a wide range of voltages, frequencies and serial protocols. It has been used to develop solutions for Radar systems, testers, Pattern Generation, digital signal processing and generating, Video processing, and many more. ESP comes as a desktop or rack mounted solution, and no special interfaces are needed.

  • Scienlab Regenerative DC Emulator

    SL1800A Series - Keysight Technologies

    Keysight's SL1800A Scienlab Regenerative DC Emulator - High-Power Series enables users to emulate the large batteries in electric vehicles. The bidirectional power flow allows emulation of both power sourcing applications, such as traction inverter test, as well as power-absorbing (sinking) applications, such as EV charging. Being regenerative, the power absorbed is delivered back to the grid, saving on energy and cooling costs. The SL1800A Series is fully integrated with the SL1040A Scienlab Charging Discovery System. The SL1093A Scienlab Charging Discover Software fully automates DC charging applications to many different test standards. With bi-directionality, integrated DC voltage and current controllers, high dynamics, and its regenerative energy feedback capacity, the Scienlab Dynamic DC Emulator provides an all-in-one system for efficient and effective testing of the power electronic components in electric vehicles (EV) and electric vehicle supply equipment (EVSE).

  • NI-9244, 400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module

    783106-01 - NI

    400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9244 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, industrial machinery, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9244 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta. You can incorporate the NI‑9244 into systems to meet standards such as IEC 61010‑1, C37.90 and C37.60, IEC 60255‑22‑(1:7), IEC 60255‑1, C37.188 Class M and P, EMC section of IEC 60870, EMC sections of IEC 61850, IEC 61000‑4‑30 Class S, and IEC 61000‑4‑7.

  • AC Power Source

    6500 series - Chroma ATE Inc.

    The global AC power testing requirements demand more sophisticated AC Power Source that is capable of simulating a wide variety of AC line conditions, harmonic waveforms, accurate power measurement and analysis. The Chroma 6500 series Programmable AC Power Source delivers the right solution to simulate all kinds of normal/abnormal input conditions and measure the critical characteristics of the product under test. It can be used for R&D design characterization, production testing, and QA verification of commercial, industrial, and aerospace electronic products. The Chroma 6500 series delivers maximum rated power for any output voltage up to 300 Vac, and at any frequency between 15Hz to 2000Hz. It is suitable for commercial applications (47-63Hz); for avionics,marine, military applications at 400Hz or higher frequency; or for electrical motor, air-conditioner test applications at 20Hz. All models generate very clean sine or square waveforms output with typical distortion less than 0.5%. The Chroma 6500 series has built-in Direct Digital Synthesis (DDS) Waveform Generator to provide user programmable high precision waveform. For testing products under AC line distortion conditions, clipped sinewave can be generated with 0% to 43% distortion and amplitude from 0% to 100%. It also can simulate all kinds of power line disturbances such as cycle dropout, transient spike, brown out, phase angle, voltage and frequency ramp up (ramp down), etc.. Up to 30 harmonic waveforms are factory installed, and testing for compliance to AC line harmonic immunity standards can be easily achieved in the field.

  • Battery Capacity Tester

    BLU-A Series - IBEKO Power AB

    The battery capacity test is performed to determine the health of a battery. DV Power’s battery load unit BLU-A is a portable, powerful, and lightweight solution for battery capacity measurement. It is applicable to any battery string such as lead-acid, Li-Ion, Ni-Cd, etc., with up to 500 V battery voltage. As a special feature, BLU100L model enables the capacity testing of a single Li-Ion cell.The capacity test is performed in an accurate and user-friendly way. Also, it is in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.Battery load unit BLU-A enables setting discharge currents up to 240 A, with a resolution 0,1 A. Furthermore, if higher currents are required, BLU-A units can be connected in parallel, or additional BXL load units can be used.The instrument offers the best power-to-weight ratio in the market. BLU-A models start from 12,8 kg / 28.2 lbs and deliver up to 28,4 kW of power.The user can select three discharge modes:Constant current,Constant power,Constant resistance.Additionally, different battery duty cycles can be simulated using user-selectable discharge profiles.The instrument monitors discharge parameters in real-time during the capacity test. A 4,3-inch touch screen display shows battery voltage, current, elapsed time, and capacity during the entire test. Also, BLU battery load unit can be used with DV-B Win software. As a result of that, a user can see a detailed numerical and graphical presentation of key parameters and can create reports in various formats.Testing with BLU-A doesn’t require a disconnection of the battery from the testing equipment.

  • Tes Rreceiver

    KH3932 - Beijing KeHuan Century EMC Technology Co,.LTD

    The KH3932 EM1 test receiver is a fully automatic test receiver and the main tool for EM1 testing. The frequency range of the KH3932 receiver is from 9kHz to 300MHz. Equipped with a power absorption clamp, it can meet the power line disturbance power test. After the artificial power network is configured, the power terminal disturbance voltage test can be carried out. The machine has fast test speed and maneuverability. Strong, stable performance, convenient test data processing and other advantages. The KH3932 receiver uses the USB interface to exchange data with the computer, which makes the transmission speed fast and the bit error rate low. Connect to the computer for testing and use the operating environment familiar to the operator to improve work efficiency.The equipped operating software saves the data of a variety of external equipment, and supports plug and play a variety of external test equipment. The software and hardware are developed by our company. The whole machine uses a fully enclosed structure, and the chassis uses highly conductive materials with good shielding effects. Due to the use of specific technologies and processes, the problem of its own resistance is fundamentally solved. The measurement results are in the international general report format, which can be saved in the computer's hard disk or transmitted through the network, printed out directly, and saved using a USB storage device. The report is rich in content and can be printed directly according to user needs without additional editing.The measurement receiver complies with the requirements of the national standard GBT6113.101 and the international standard CISPR16-1.

  • Ultra-Low Power Computing Module

    CM22303 - LinkedHope Intelligent Technologies Co.,Ltd.

    CM22303 uses Intel® 7th generation Kaby Lake-Y platform and Core M Ultra low-power SoC processors, and integrates the full functions of CPU, GPU and South/North Bridge on a single chip. The processor provides powerful computing and display performance with dual-core and four threads configuration. Its turbo frequency can boost up to 3.6 GHz and the display output resolution can be up to 4K. CM22303 has an amazing thermal design power consumption of only 4.5W (TDP) and can be used for a variety of high-performance fanless designs. SPI BIOS is designed on board to support dual-channel low voltage on board memory (up to 16GB), Gigabit Ethernet, TPM module and other functions. With high-performance and low power consumption, it can be widely used in the field of low power embedded systems. Meanwhile, CM22303 adopts COM Express standard and is compatible with Type10 pin out definition, and also provides rich peripheral interfaces such as USB3.0/2.0, PCIe, SATA, HD Audio etc.

  • Regenerative Power System

    IT6000B Series - I-TECH Electronic Co., Ltd

    From the perspective of improving customer experience, ITECH launches a new incorporated product--IT6000B series. IT6000B integrates bidirectional power supply and regenerative electronic load into one 3U unit. It is also a very powerful one. Only a button is needed to switch between the bidirectional power supply and the regenerative electronic load. It can be used not only as a stand-alone powerful bidirectional power supply, as a source to provide power; but also as an independent regenerative electronic load, to absorb the consumed energy and feedback cleanly to the grid. IT6000B offers standard two-quadrants functionality. IT6000B provides 7 voltage ranges, up to 2250V, supports master-slave parallel with even current distribution up to 1152kW. Built-in waveform generator supports generating arbitrary waveforms, and imports LIST files for waveforms via USB interface. IT6000B is the combination of reliability, high efficient setting, safe and multiple measurement functions. IT6000B is a family of bi-directional, regenerative power system with excellent performance, extensively used in aspects of high power battery, automotive electronics, green energy, high speed testing etc.

  • Natural Cooling Input 380VAC 3 Phase to Output 190-300VDC 10A-40A Rectifier Battery Charger

    SD230D20ZZ - Zhejiang Sandi Electric Co., Ltd

    SANDI “SD” series intelligent high-frequency switch power supply modules are specially developed to meet the demands of modern DC system. The charger rectifiers are designed with world leading patent technology “resonant voltage type soft switching power supply technology”. They feature high efficiency and stability, intelligent control, small size and light weight. Standard RS-485 interface, easy to connect with automation system. “Four remotes” functions, intelligent management. The products are widely used in power plant, substations and etc..Main characteristic of the moduleModularization design, realize N+1 backup;The friendly man-machine interface. Large screen to show, realize man-machine dialogue operate really.RS-485 inrerface, realize “4 remote” function with monitor machine.High efficiency, Nearly 95%-96%;Lightly, 230V/10A natural cooling module only 9kg;Little volume, 230V/10A natural cooling module dimension only 325mm×230mm×130mm;After the full bridge rectifying circuit rectifies 3-phase AC to DC, then adjusted by reactive PFC, power factor>0.94;Function against reverse pour: each module has been added diode against reverse pour at output terminal.LED digital screen, digital calibrate, stable current ,fault alarm Main characteristic of the ModulesThe friendly man-machine interface. LED digital screen, digital calibrate, stable current ,fault alarmHigh efficiency, up to 95%-96%;Light weight, Small sizeAfter the full bridge rectifying circuit rectifies 3-phase AC to DC, then adjusted by reactive PFC, power factor>0.94;Unequal current ratio of parallel connection<+/-3%, can ensure twenty modules work well by parallel connection.Multiple protections including over/under voltage, current limiting, short-circuit, parallel protection, over-temperature protection.Output over-voltage protectionTo prevent the disastrous accident caused by output overvoltage, there is overvoltage protection circuit in the module. Once the output voltage is higher than the threshold, the module locks up automatically and fault indication light is on, the faulty module quits work automatically and doesn’t affect the normal operation of the entire system.Output current limiting protectThe output current cannot increase infinitely. The maximum value of the output current of each module is limited to the rated output current 105%, in this range, the output current value of the module is continuously adjustable. If the load output of the module, the module will play down the output voltage.Output short-circuit protectionWhen short circuit, the output voltage drops to 0 immediately. Limit the short circuit current under 15% of rated output current. The module will not be damaged under short circuit state for a time, and resumes to work automatically after debugging. Module parallel protectionThere is parallel protection circuit in each module to ensure that when the fault module quits the system, the normal work of other modules and the system won’t be effect.Output over-current protectionThe output current cannot increase infinitely. If overloaded, the output voltage decreases automatically to protect the power components. The over current protection can be resumed automatically.